How to Calculate the Right Antiscalant Dose for Your RO Plant

Technical Guides
ALS 710 مانع تكلّس للمياه قليلة الملوحة عبوة 20 كجم من إنتاج شركة الأساس الثمين
Technical Library · Technical Guide · 2026

How to Calculate the Right Antiscalant Dose for Your RO Plant

One formula links the dose to the feed flow, plus a fully worked example for a 250 m³/day plant, right down to setting the dosing pump.

Technical Guide4 min readData tablesFAQALS engineering team
⚡ Short answer

The daily antiscalant quantity is calculated as:
Quantity (kg/day) = Dose (ppm) × Feed flow (m³/day) ÷ 1000
Example: a plant with a feed flow of 333 m³/day at 4 ppm needs 1.33 kg per day. The typical dose is 2–10 ppm and is set from the water analysis and the recovery rate.

Part 01

Step 1: Which flow is the dose based on?

This is the most common mistake operators make. The dose is calculated on the feed flow — all the water entering the plant — not on the permeate.

The reason is simple: the antiscalant is injected into the feed line before the pump, so it mixes with the entire incoming flow.

Warning: if you calculate on permeate in a plant running at 75% recovery, you will dose only three quarters of what is needed — and believe you are protected when you are not.

Converting permeate to feed flow

Feed flow = Permeate flow ÷ Recovery rate
Permeate Recovery Feed
250 m³/day 75% 333 m³/day
250 m³/day 50% 500 m³/day
100 m³/day 40% (seawater) 250 m³/day
Part 02

Step 2: How is the dose in ppm determined?

The dose is not a fixed number — it depends on how close the concentrate is to saturation. Indicative ranges:

Water condition Approximate dose
Low-salinity water, low hardness, recovery ≤ 50% 2 – 3 ppm
Typical groundwater, recovery 65–75% 3 – 5 ppm
High hardness or alkalinity, recovery > 75% 5 – 8 ppm
Barium/strontium or high silica present 6 – 10 ppm

These ranges are for guidance only. The exact figure comes from running the water analysis through saturation-calculation software — a service we provide free of charge to our customers.

Part 03

Step 3: A fully worked example

Given:

  • Groundwater desalination plant, output 250 m³/day
  • Recovery rate 75%
  • Dose recommended from the analysis: 4 ppm
  • Antiscalant: ALS 720 — 20 kg pack

Feed flow

250 ÷ 0.75 = 333 m³/day

Daily quantity

(4 × 333) ÷ 1000 = 1.33 kg/day

Monthly and annual consumption

1.33 × 30 = 40 kg per month ≈ 2 packs
1.33 × 365 = 486 kg per year ≈ 24 packs

Setting the dosing pump

If you prepare a 10% dilution (10 kg of product in 100 L of water):
Daily solution volume = 1.33 ÷ 0.10 = 13.3 L/day
Pump rate = 13.3 ÷ 24 = 0.55 L/h ← this is the pump setting

Part 04

Step 4: The three mistakes we see all the time

1. Underdosing — the most dangerous

Usually caused by calculating on permeate instead of feed, or by an uncalibrated pump that delivers less than its setting. The result is slow scaling you only notice months later, when the damage is already done.

2. Overdosing — waste with no benefit

Many believe more means better protection. It does not: antiscalants work by threshold inhibition, and beyond a certain point extra product adds nothing. Worse, heavy overdosing can feed biological growth on the membrane.

3. Uncalibrated dosing pump

Dosing pumps lose accuracy over time — worn valves, scaled injection points or changes in back-pressure. The result: what is set on the dial is not what is actually dosed.

Practical check: mark the solution level in the dosing tank and measure how much it drops after 24 hours. Compare with the theoretical figure. If the difference exceeds 10%, calibrate the pump.

Part 05

Step 5: Quick daily consumption table

For a quick estimate at 4 ppm:

Feed flow kg/day 20 kg packs per month
50 m³/day 0.20 0.3
100 m³/day 0.40 0.6
250 m³/day 1.00 1.5
500 m³/day 2.00 3.0
1000 m³/day 4.00 6.0
FAQ

Frequently asked questions

Should I dilute the product or dose it neat?

Dilution is better in practice: it gives more accurate dosing and reduces scaling of the pump head. 5–10% is common. Use permeate for dilution, not raw water.

How long does the diluted solution stay usable?

Prepare only enough for one week. Diluted solution left standing for long is prone to bacterial growth.

Does the dose change between summer and winter?

Yes, slightly. Higher water temperature lowers the solubility of calcium carbonate and increases scaling risk. Review the dose when the source temperature changes by more than 5 degrees.

What if the well salinity changes?

Repeat the analysis and recalculate the dose. Many wells in Libya become gradually saltier over the years, and a dose calculated three years ago may no longer be enough.

We calculate the exact dose for you — free

Send us your water analysis and plant data, and we will give you the recommended dose and the pump setting.

ALS Products

Prepared by the technical team at Al-Asas Al-Thameen for Water Treatment (ALS) — a Libyan manufacturer of water treatment chemicals and desalination plants since 2013.