One formula links the dose to the feed flow, plus a fully worked example for a 250 m³/day plant, right down to setting the dosing pump.
The daily antiscalant quantity is calculated as:
Quantity (kg/day) = Dose (ppm) × Feed flow (m³/day) ÷ 1000
Example: a plant with a feed flow of 333 m³/day at 4 ppm needs 1.33 kg per day. The typical dose is 2–10 ppm and is set from the water analysis and the recovery rate.
Step 1: Which flow is the dose based on?
This is the most common mistake operators make. The dose is calculated on the feed flow — all the water entering the plant — not on the permeate.
The reason is simple: the antiscalant is injected into the feed line before the pump, so it mixes with the entire incoming flow.
Warning: if you calculate on permeate in a plant running at 75% recovery, you will dose only three quarters of what is needed — and believe you are protected when you are not.
Converting permeate to feed flow
| Permeate | Recovery | Feed |
|---|---|---|
| 250 m³/day | 75% | 333 m³/day |
| 250 m³/day | 50% | 500 m³/day |
| 100 m³/day | 40% (seawater) | 250 m³/day |
Step 2: How is the dose in ppm determined?
The dose is not a fixed number — it depends on how close the concentrate is to saturation. Indicative ranges:
| Water condition | Approximate dose |
|---|---|
| Low-salinity water, low hardness, recovery ≤ 50% | 2 – 3 ppm |
| Typical groundwater, recovery 65–75% | 3 – 5 ppm |
| High hardness or alkalinity, recovery > 75% | 5 – 8 ppm |
| Barium/strontium or high silica present | 6 – 10 ppm |
These ranges are for guidance only. The exact figure comes from running the water analysis through saturation-calculation software — a service we provide free of charge to our customers.
Step 3: A fully worked example
Given:
- Groundwater desalination plant, output 250 m³/day
- Recovery rate 75%
- Dose recommended from the analysis: 4 ppm
- Antiscalant: ALS 720 — 20 kg pack
Feed flow
250 ÷ 0.75 = 333 m³/day
Daily quantity
(4 × 333) ÷ 1000 = 1.33 kg/day
Monthly and annual consumption
1.33 × 30 = 40 kg per month ≈ 2 packs
1.33 × 365 = 486 kg per year ≈ 24 packs
Setting the dosing pump
If you prepare a 10% dilution (10 kg of product in 100 L of water):
Daily solution volume = 1.33 ÷ 0.10 = 13.3 L/day
Pump rate = 13.3 ÷ 24 = 0.55 L/h ← this is the pump setting
Step 4: The three mistakes we see all the time
1. Underdosing — the most dangerous
Usually caused by calculating on permeate instead of feed, or by an uncalibrated pump that delivers less than its setting. The result is slow scaling you only notice months later, when the damage is already done.
2. Overdosing — waste with no benefit
Many believe more means better protection. It does not: antiscalants work by threshold inhibition, and beyond a certain point extra product adds nothing. Worse, heavy overdosing can feed biological growth on the membrane.
3. Uncalibrated dosing pump
Dosing pumps lose accuracy over time — worn valves, scaled injection points or changes in back-pressure. The result: what is set on the dial is not what is actually dosed.
Practical check: mark the solution level in the dosing tank and measure how much it drops after 24 hours. Compare with the theoretical figure. If the difference exceeds 10%, calibrate the pump.
Step 5: Quick daily consumption table
For a quick estimate at 4 ppm:
| Feed flow | kg/day | 20 kg packs per month |
|---|---|---|
| 50 m³/day | 0.20 | 0.3 |
| 100 m³/day | 0.40 | 0.6 |
| 250 m³/day | 1.00 | 1.5 |
| 500 m³/day | 2.00 | 3.0 |
| 1000 m³/day | 4.00 | 6.0 |
Frequently asked questions
Should I dilute the product or dose it neat?
Dilution is better in practice: it gives more accurate dosing and reduces scaling of the pump head. 5–10% is common. Use permeate for dilution, not raw water.
How long does the diluted solution stay usable?
Prepare only enough for one week. Diluted solution left standing for long is prone to bacterial growth.
Does the dose change between summer and winter?
Yes, slightly. Higher water temperature lowers the solubility of calcium carbonate and increases scaling risk. Review the dose when the source temperature changes by more than 5 degrees.
What if the well salinity changes?
Repeat the analysis and recalculate the dose. Many wells in Libya become gradually saltier over the years, and a dose calculated three years ago may no longer be enough.
We calculate the exact dose for you — free
Send us your water analysis and plant data, and we will give you the recommended dose and the pump setting.